Thesen-Kramer Residence
PROJECT |
||
Project Name: | Thesen-Kramer Residence | |
Completion Date: | 2010 |
|
Building Type: | SF Residential |
|
Project Description: | The first house in Palo Alto built to the Passive House Standard is known as Project Green Home. |
|
Location: |
94306
Palo Alto, CA
|
|
No. of units: | 1 |
|
Construction Type: | Stick frame |
|
Construction Cost: |
TEAM |
|
Owner: | Sven Thesen & Kate Kramer |
Architect/Designer: | Arkin Tilt Architects |
Engineer/s: | Dan Johnson |
PH Consultant: | Dan Johnson |
Contractor: | Joshua Moore |
Other: | |
Miscelaneous: |
PREDICTED PERFORMANCE |
METRIC VALUES |
|
Treated Floor Area: | 2113 ft2 |
196 m2 |
Typical Calc. Area: | 2492 ft2 |
|
Exterior Walls: | 18.00 hr.ft2.ºF/BTU |
0.315 W/m2K |
Floor/Slab: | 28.00 hr.ft2.ºF/BTU |
0.203 W/m2K |
Roof: | 45.00 hr.ft2.ºF/BTU |
0.126 W/m2K |
Overall Window: | 4.00 hr.ft2.ºF/BTU |
1.420 W/m2K |
Window Frame: | 4.55 hr.ft2.ºF/BTU |
1.248 W/m2K |
Window SHGC: | 0.48 |
0.48 % |
Entry Door: | 1.00 hr.ft2.ºF/BTU |
5.678 W/m2K |
Ventilation: | 69.00 % |
69.00 % |
Heating Source: | Electric Heat Pump |
|
Cooling Source: | Electric Heat Pump |
|
Hot Water Source: | Electric Heat Pump |
|
Airtightness: | 0.60 ACH50 |
0.60 ACH50 |
Green materials: | ||
Annual Heat Demand: | 3.94 kBTU/ft².yr |
12.43 kWh/m2yr |
Heating Load: | 3.00 BTU/ft².hr |
9.46 W/m2 |
Primary Energy Value: | 27.00 kBTU/ft².yr |
85.17 kWh/m2yr |
CERTIFICATION |
|
Certification: | 0 |
Issued by: |