Wood Guest House
PROJECT |
||
Project Name: | Wood Guest House | |
Completion Date: | 2011 |
|
Building Type: | Single-Family |
|
Project Description: | ||
Location: |
CA
Sonoma, CA
|
|
No. of units: | 1 |
|
Construction Type: | Stick frame |
|
Construction Cost: |
TEAM |
|
Owner: | James & Jennifer Jandak-Wood |
Architect/Designer: | Jarrod Denton, Signum Architecture |
Engineer/s: | |
PH Consultant: | Graham Irwin, Essential Habitat |
Contractor: | Rick Milburn, PassivWorks |
Other: | |
Miscelaneous: |
PREDICTED PERFORMANCE |
METRIC VALUES |
|
Treated Floor Area: | 562 ft2 |
52 m2 |
Typical Calc. Area: | 659 ft2 |
|
Exterior Walls: | 37.00 hr.ft2.ºF/BTU |
0.153 W/m2K |
Floor/Slab: | 39.00 hr.ft2.ºF/BTU |
0.146 W/m2K |
Roof: | 70.00 hr.ft2.ºF/BTU |
0.081 W/m2K |
Overall Window: | 7.00 hr.ft2.ºF/BTU |
0.811 W/m2K |
Window Frame: | 6.00 hr.ft2.ºF/BTU |
0.946 W/m2K |
Window SHGC: | 0.52 |
0.52 % |
Entry Door: | 0 W/m2K |
|
Ventilation: | 89.10 % |
89.10 % |
Heating Source: | A/A Heat Pump |
|
Cooling Source: | A/A Heat Pump |
|
Hot Water Source: | Solar w/ Tankless Electric |
|
Airtightness: | 0.46 ACH50 |
0.46 ACH50 |
Green materials: | ||
Annual Heat Demand: | 4.85 kBTU/ft².yr |
15.30 kWh/m2yr |
Heating Load: | 3.41 BTU/ft².hr |
10.76 W/m2 |
Primary Energy Value: | 19.22 kBTU/ft².yr |
60.63 kWh/m2yr |
CERTIFICATION |
|
Certification: | |
Issued by: | PHIUS+ |